Quote:
Originally Posted by Lampshade
I love the build, looks great so far. Dave has a very good idea with the baffles in the sump, one of the biggest cause for bubbles in my tank was the waterfall off my last baffle, this idea fixes that. One thing you could do to "failsafe" your ATO is to have your water enter the sump through a float valve AFTER your ATO setup. Since you won't be around for weekends, it could be very bad to have a switch stick on. Here's what i use for mine http://www.jlaquatics.com/product/ro...O+Filters.html Up to you really, most people run just the ATO without problems.
|
If I only had one float switch on the ATO system I would probably consider the float valve, but this ATO system comes with 2 float switches, the 2nd acts as a failsafe to shut the pump off in case the first one gets stuck in the "on" position. If they both get stuck on, well I'm SOL sorta, but at the same time, my reservoir will be not larger than 5-7G. That is only 2-3% of my total system volume which should never bring my tank out of the 1.022-1.026 range 'safe range'.