Quote:
Originally Posted by Milad
Could I just not have a couple holes in the pipe at the top of the tank to break the siphon? or is it because it goes so far down that the holes wont work.
|
Quote:
Originally Posted by Milad
when the pump is on, the holes are jsut under the water, when the pump is off the holes will be above the water
|
Sure..that will work. As will a check valve. Put both in place. I'm just saying that I would not want to be THAT dependent on those working...because if they fail during a power outage you are talking about complete death of the tank and flood damage to your house.
The holes WILL plug up. You'll need to keep those cleaned out all the time.
Check valves get stuck open. Especially if they don't get exercised much.
My returns go over the top edge of the aquarium and exit only 2" below water line. Even if my check valve fails, there is no way I can siphon more than 2" of water from the tank. Design to be fail proof. You'll sleep better.
__________________
400 gal reef. Established April, 2007. 3 Sequence Dart, RM12-4 skimmer, 2 x OM4Ways, Yellow Tang, Maroon Clown (pair), Blonde Naso Tang, Vlamingi Tang, Foxface Rabbit, Unicorn Tang, 2 Pakistani Butterflies and a few coral gobies
My Tank:
http://www.canreef.com/vbulletin/showthread.php?t=28436