Personally I would use gate valves instead of ball valves. I know they are more expensive but are so much easier to tweak flow rates.
Im not trying to start any arguments over this, just making a comment.
Gate valves are not designed to be used as a throttling valve they are designed to be a 100% open or 100% closed, if you are looking for a valve that is designed to be throttling us a globe valve.
Now I am new to SW fish tanks but I do have a good idea of affects of flow through valves and I do know that when you use a gate valve you with wash out the seat on the valve then it becomes very difficult or impossible to get isolation.