01-15-2012, 05:44 PM
So I've plumbed my tank without cementing any of the fittings together. I was hoping to get some opinions or feedback to make sure I've done everything right before I cement everything. Below are some pictures with some of my comments.


I'm wondering how I can lower the tops of these caps so they're not sticking up way above the tank?
http://farm8.staticflickr.com/7150/6702244545_cf828b5a91.jpg



The picture below shows how far they're sticking up.
http://farm8.staticflickr.com/7029/6702251549_49dd05309b.jpg


The picture below shows where the waterline should be approx. I'm wondering how deep I can submerge the siphon pipe?
http://farm8.staticflickr.com/7024/6702247927_f767be5ea5.jpg


http://farm8.staticflickr.com/7165/6702255903_07e4caa2fe.jpg


http://farm8.staticflickr.com/7030/6702241173_bd2ede68b8.jpg


The picture below shows my reservoir. The larger half will hold RO/DI water and the chamber to the right will hold saltwater mix
http://farm8.staticflickr.com/7027/6702262729_015aab9ef3.jpg



I've plumbed it in such a way so after I've pumped out 10% water volume for water changes I simply need to open the valve to allow the water from the reservoir above to drain back into the sump.
http://farm8.staticflickr.com/7004/6702268487_6b29be6162.jpg


http://farm8.staticflickr.com/7031/6702271673_664dfaf789.jpg


The plumbing with the grey 90 degree elbow will be used for ATO however how do I get my pvc plumbing to merge with a 1/4" waterline?
http://farm8.staticflickr.com/7017/6702279249_2cb26dc2d3.jpg


Again, this is the plumbing coming from my RO reservoir for ATO. The bottom plumbing will be for emergency overflow in case the sump overflows. It will run to a floor drain.
http://farm8.staticflickr.com/7165/6702281341_2a62f3c1c8.jpg


Comments/suggestions appreciated.

reefme
01-15-2012, 07:08 PM
for my 2 little pennies I would use some flex tubings for safety not 100% PVC pipes.

molotov
01-15-2012, 11:10 PM
I plan on using spa-flex through the wall to my sump. I will be using for both my return and my overflow plumbing.

Unitt
01-16-2012, 01:45 AM
What makes flex pipe safer?


---
I am here: http://maps.google.com/maps?ll=51.302021,-114.009096

WindowMaker
01-16-2012, 09:26 AM
Good question, I'd like to know the answer to that one too.

reefme
01-16-2012, 12:13 PM
If your tanks moves or other end moves you still safe right with flex pipe.

reefwars
01-16-2012, 01:36 PM
So I've plumbed my tank without cementing any of the fittings together. I was hoping to get some opinions or feedback to make sure I've done everything right before I cement everything. Below are some pictures with some of my comments.


I'm wondering how I can lower the tops of these caps so they're not sticking up way above the tank?
http://farm8.staticflickr.com/7150/6702244545_cf828b5a91.jpg


.


you can get caps that will fit into your " t " on top of your durso, they are slip fit and then just drill a very tiny hole into the top.thats what ive always done for durso's:) looks good though man and cheers:)

molotov
01-16-2012, 04:22 PM
you can get caps that will fit into your " t " on top of your durso, they are slip fit and then just drill a very tiny hole into the top.thats what ive always done for durso's:) looks good though man and cheers:)

I have the slip caps but I've decided to use threaded in case I ever need to service the standpipe. All I would have to do is unthread the cap and I'd be able to get inside the pipe. If it were sealed with a slip cap I'd have to cut the pipe or build a new one.

parkinsn
01-16-2012, 04:59 PM
Can you shorten the pipe between the "T" and the Threaded adapter?

Why not get a threaded reducer for the top of the "T" and then your theaded cap? The cap is only for adjusting your air to the pipe. Looks like 1-1/4" pipe? Get a 1-1/4" to 1" threaded reducer change your cap size down to 1"?

Or just leave it all not glued. Get a slip cap. With 3 down pipes you will likely sell the tank before you have to service them. There is really no need to have it glued, if it leaks it will just leak back into the overflow and not your floor. Obviously glue below the BH.

What kind of servicing do you think your going to need to do? If something gets caught in the pipe, it will likely be at the valve which I assume will be partly closed. You have true union valves so you will be able to disconnest there anyway.

Reefer Rob
01-16-2012, 05:00 PM
Why do you have shut offs on all your outlets? I would have 2 with no valve and 1 slightly lower (with no Durso and low enough to not cause a vortex) in the over flow with a valve to adjust the level. The 2 higher outlets are only in case the one with the valve clogs. Use all slip inside the overflow and seal with a couple of wraps of Teflon tape only.

molotov
01-17-2012, 04:08 AM
Can you shorten the pipe between the "T" and the Threaded adapter?

Why not get a threaded reducer for the top of the "T" and then your theaded cap? The cap is only for adjusting your air to the pipe. Looks like 1-1/4" pipe? Get a 1-1/4" to 1" threaded reducer change your cap size down to 1"?

Or just leave it all not glued. Get a slip cap. With 3 down pipes you will likely sell the tank before you have to service them. There is really no need to have it glued, if it leaks it will just leak back into the overflow and not your floor. Obviously glue below the BH.

What kind of servicing do you think your going to need to do? If something gets caught in the pipe, it will likely be at the valve which I assume will be partly closed. You have true union valves so you will be able to disconnest there anyway.

So I'm going to do as Parkinsn suggested and get rid of the threaded cap and just do the slip cap. This will save me an inch; which is A LOT!!

Also I will probably not glue it so if I ever need to take a peek down there I can.

For the person that asked why I have valves plumbed to every standpipe it's so that I can test the fail safes. I will be able to create a scenario where if one pipe fails the other two will work. If two pipes fail I can safely rely on the emergency pipe. it's just so I can create different scenarios and make sure everything is working as it should. Peace of mind!