01-15-2012, 05:44 PM
So I've plumbed my tank without cementing any of the fittings together. I was hoping to get some opinions or feedback to make sure I've done everything right before I cement everything. Below are some pictures with some of my comments.
I'm wondering how I can lower the tops of these caps so they're not sticking up way above the tank?
http://farm8.staticflickr.com/7150/6702244545_cf828b5a91.jpg
The picture below shows how far they're sticking up.
http://farm8.staticflickr.com/7029/6702251549_49dd05309b.jpg
The picture below shows where the waterline should be approx. I'm wondering how deep I can submerge the siphon pipe?
http://farm8.staticflickr.com/7024/6702247927_f767be5ea5.jpg
http://farm8.staticflickr.com/7165/6702255903_07e4caa2fe.jpg
http://farm8.staticflickr.com/7030/6702241173_bd2ede68b8.jpg
The picture below shows my reservoir. The larger half will hold RO/DI water and the chamber to the right will hold saltwater mix
http://farm8.staticflickr.com/7027/6702262729_015aab9ef3.jpg
I've plumbed it in such a way so after I've pumped out 10% water volume for water changes I simply need to open the valve to allow the water from the reservoir above to drain back into the sump.
http://farm8.staticflickr.com/7004/6702268487_6b29be6162.jpg
http://farm8.staticflickr.com/7031/6702271673_664dfaf789.jpg
The plumbing with the grey 90 degree elbow will be used for ATO however how do I get my pvc plumbing to merge with a 1/4" waterline?
http://farm8.staticflickr.com/7017/6702279249_2cb26dc2d3.jpg
Again, this is the plumbing coming from my RO reservoir for ATO. The bottom plumbing will be for emergency overflow in case the sump overflows. It will run to a floor drain.
http://farm8.staticflickr.com/7165/6702281341_2a62f3c1c8.jpg
Comments/suggestions appreciated.
I'm wondering how I can lower the tops of these caps so they're not sticking up way above the tank?
http://farm8.staticflickr.com/7150/6702244545_cf828b5a91.jpg
The picture below shows how far they're sticking up.
http://farm8.staticflickr.com/7029/6702251549_49dd05309b.jpg
The picture below shows where the waterline should be approx. I'm wondering how deep I can submerge the siphon pipe?
http://farm8.staticflickr.com/7024/6702247927_f767be5ea5.jpg
http://farm8.staticflickr.com/7165/6702255903_07e4caa2fe.jpg
http://farm8.staticflickr.com/7030/6702241173_bd2ede68b8.jpg
The picture below shows my reservoir. The larger half will hold RO/DI water and the chamber to the right will hold saltwater mix
http://farm8.staticflickr.com/7027/6702262729_015aab9ef3.jpg
I've plumbed it in such a way so after I've pumped out 10% water volume for water changes I simply need to open the valve to allow the water from the reservoir above to drain back into the sump.
http://farm8.staticflickr.com/7004/6702268487_6b29be6162.jpg
http://farm8.staticflickr.com/7031/6702271673_664dfaf789.jpg
The plumbing with the grey 90 degree elbow will be used for ATO however how do I get my pvc plumbing to merge with a 1/4" waterline?
http://farm8.staticflickr.com/7017/6702279249_2cb26dc2d3.jpg
Again, this is the plumbing coming from my RO reservoir for ATO. The bottom plumbing will be for emergency overflow in case the sump overflows. It will run to a floor drain.
http://farm8.staticflickr.com/7165/6702281341_2a62f3c1c8.jpg
Comments/suggestions appreciated.